Electrical performance
Characteristic impedance: 120Ω ± 15%
Conductor DC resistance: At 20℃, it does not exceed about 26Ω per kilometer
Capacitance: At 1kHz, the nominal capacitance between conductors is about 30nF/km, and the nominal capacitance between conductors and shielding is about 50nF/km
Propagation speed: The nominal propagation speed is about 66%
Delay time: The nominal delay time is about 4.5ns/m
Attenuation: The nominal attenuation at 1MHz is about 12dB/km
Working voltage: The maximum working voltage is generally 300V
Working current: The recommended maximum working current is 5A (@25℃)
Structural characteristics
Conductor: 3 pairs of 6 cores (3x2x21AWG) stranded tinned copper wire, in line with VDE0295 Class 5 standard, to ensure good conductivity and flexibility.
Insulation: Polyethylene (PE) or PE insulation material imported from Germany is usually used. The thickness of the insulation layer is uniform, which can effectively prevent short circuits and signal interference between conductors.
Shielding: Generally, double shielding is adopted, which is tinned copper wire precision weaving and aluminum-plastic composite tape wrapping shielding, which can effectively prevent the influence of external electromagnetic interference on the signal and reduce the signal radiation outward.
Drain wire: Tinned copper wire precision bundle guide wire is used as grounding protection to enhance the anti-interference ability of the cable.
Outer sheath: Mostly industrial gray PVC outer sheath, which has the characteristics of wear resistance, weather resistance, corrosion resistance, etc., and can adapt to different use environments. The color of the outer sheath can also be customized according to customer requirements.
Mechanical properties
Minimum bending radius: Generally 8 times the cable diameter during installation.
Working temperature: Usually between – 30℃ and +70℃.
Tensile strength: Meet certain tensile requirements to ensure that the cable will not break easily during normal use and installation.
Compression resistance: Can withstand certain pressure, such as ground pressure or extrusion of other objects during laying.
Others
Compliant standards: Compliant with UL AWM 2919 and other relevant standards.
Application scenarios: Applicable to industrial automation control network communication, building automation network communication, intelligent transportation system, power automation and other fields, which can realize stable and reliable data transmission between devices.
Hot Selling Quality 3×0.75mm² 21AWG Bare Copper Pe Pvc Copper Foil Electric Cable Rs485 Twisted Shield Cable for monitor
RS485 cables are used in
Industrial automation: networking of production equipment, remote I/O module control
Building automation: HVAC system control, lighting system control, security system integration
Traffic management: traffic light control, electronic police system
Energy management: solar power generation system, smart grid
Medical equipment: networking of medical instruments, ward equipment monitoring
Agricultural automation: environmental monitoring and irrigation control, aquaculture environment monitoring
Reviews