Electrical performance
Characteristic impedance: 120 ohms.
Conductor DC resistance: At 20℃, no more than 25.7Ω per kilometer.
Capacitance: At 1kHz, the nominal capacitance between conductors is about 35nF/km, and between conductors and shields is about 65nF/km.
Propagation speed: The nominal propagation speed is about 66%.
Delay time: The nominal delay time is about 5.0ns/m.
Attenuation: The nominal attenuation at 1MHz is about 15dB/km.
Working voltage: The maximum working voltage is generally 300V.
Working current: The recommended maximum working current is 3.5A (@25℃).
Structural characteristics
Conductor: 2 pairs of 4 cores (2x2x18AWG) stranded tinned copper wires. If some use 18AWG (7×26AWG) tinned copper wire stranded conductors to ensure good conductivity and flexibility.
Insulation: Polyethylene (PE) insulation is usually used, and the thickness of the insulation layer is uniform, which can effectively prevent short circuits and signal interference between conductors.
Shielding: Generally, double shielding is used, with a shielding rate of 90% for aluminum foil/polyester composite tape + tinned copper braided mesh, which can effectively prevent the influence of external electromagnetic interference on the signal and reduce the radiation of the signal.
Drain line: 18AWG (7×26AWG) tinned copper wire stranded conductor is used as grounding protection to enhance the anti-interference ability of the cable.
Outer sheath: Mostly industrial black PVC outer sheath, which has the characteristics of wear resistance, weather resistance, corrosion resistance, etc., and can adapt to different use environments. The color of the outer sheath can also be customized according to customer requirements.
Mechanical properties
Minimum bending radius: Generally 10 times the cable diameter during installation.
Working temperature: Usually between -20℃~+70℃.
Others
Compliance with standards: Comply with UL AWM 2919 and other relevant standards.
Application scenarios: Suitable for communication networks such as building automation, industrial control networks, and power automation, and can achieve stable and reliable data transmission between devices
Best-Selling Custom 2x1mm² 18Awg Bare Copper Pe Pvc Ai Foil Shield Control Cable Twisted Shield Cable for Switch
RS485 cables are used in
Industrial automation: networking of production equipment, remote I/O module control
Building automation: HVAC system control, lighting system control, security system integration
Traffic management: traffic light control, electronic police system
Energy management: solar power generation system, smart grid
Medical equipment: networking of medical instruments, ward equipment monitoring
Agricultural automation: environmental monitoring and irrigation control, aquaculture environment monitoring
Reviews